Scoping is where most applicants get tripped up. The rule is straightforward: everything is in scope unless you have specifically excluded it in a properly segregated sub-set. This guide covers what that means in practice - devices, cloud services, home workers, BYOD, subsets and what you cannot exclude.

FROM £395 + VATIASME APPROVED BODYWHOLE ORG OR SUBSETBYOD & CLOUD COVERED
5
Controls Assessed
L2/3
OSI Segregation Required
100%
Cloud Services In Scope
Yes
BYOD Staff Devices In Scope
// The Golden Rule

WHAT IS INCLUDED IN CYBER ESSENTIALS SCOPE

This is the starting point for every Cyber Essentials assessment. If you have not formally excluded something in a properly segregated sub-set, it is in scope - regardless of whether it feels relevant.

The scope of a Cyber Essentials assessment covers all the IT infrastructure your organisation uses to conduct its business. That means every device, every cloud service, every network segment - unless you have taken specific technical steps to exclude part of it.

The easiest way to approach scoping is to assume everything is included, then identify what you need to exclude and whether you can legitimately do so. Trying to work backwards - starting from what you want to include - is where most applicants run into problems.

Whole Organisation vs Subset

Most organisations should aim for whole organisation scope. This gives maximum protection and, for UK-domiciled organisations with annual turnover below £20 million, qualifies you for the included cyber liability insurance that comes with certification.

Where the whole organisation genuinely cannot be in scope - for example because some devices run unsupported software that cannot meet the requirements - you can certify a sub-set. A sub-set is a part of the organisation whose network is segregated from the rest by a firewall or VLAN. The scope must then describe what is excluded: for example, "Whole organisation excluding the development network".

There is one recognised exception: a segregated guest network (hotel wifi, school visitor network) that has no access to organisational data can be excluded and the scope description can still read "whole organisation".

THE KEY PRINCIPLE

Everything is in scope, unless it is specifically excluded in a sub-set.

If you have not taken specific technical steps to remove something from scope, it is included - even if it feels peripheral to your main business operations.

Talk to an Assessor →
  • WHOLE ORG: preferred approach

    No networks excluded. Qualifies for free cyber liability insurance (turnover <£20m, UK-domiciled). Guest/student wifi with no organisational data access can be excluded and scope is still "whole organisation".

  • SUBSET: when needed

    Segregated part of the network using a firewall or VLAN at Layer 2/3. All inbound and outbound internet access must be blocked on the excluded segment to retain "whole organisation" description - otherwise the scope is "excluding X".

// What's Always In Scope

WHAT IS ALWAYS IN SCOPE

The following are always in scope for Cyber Essentials regardless of how your network is structured - including BYOD devices, cloud services, and home workers. No segregation method removes them.

// End-User Devices

LAPTOPS, DESKTOPS, PHONES & TABLETS

All end-user devices that access organisational data or services are in scope. The scope must include end-user devices - certifying server systems only without including the devices of the people who administer them is not permitted.

// Cloud

ALL CLOUD SERVICES

Every cloud service your organisation uses is in scope - Microsoft 365, Google Workspace, cloud storage, SaaS applications, MDM solutions. You are responsible for ensuring Cyber Essentials controls are applied to these services even if the provider manages the infrastructure.

// Remote Workers

HOME WORKERS

Anyone working from home for any amount of time is a home worker for the purposes of Cyber Essentials. All devices they use for work - including personal phones used for work email - are in scope. Where a home worker connects via a 4G/5G mobile network, the device firewall is the boundary.

// BYOD

STAFF BYOD (PERSONALLY-OWNED DEVICES)

Personally-owned devices used to access organisational data or services are in scope. This cannot be avoided by policy - if the device accesses work email or any organisational system, it is in scope. Staff BYOD cannot be moved out of scope.

// Virtual

VMs, CONTAINERS AND VDI ENDPOINTS

Virtual machines and containers are in scope - the controls apply in the same way as for physical devices. When using Virtual Desktop Infrastructure (VDI), all end-user devices that access the VDI are in scope, not just the virtual desktop server itself.

// Third Parties

CONTRACTORS WITH COMPANY DEVICES

Contractors using company-issued devices, or whose devices are administered by your organisation, are in scope. Devices the contractor owns and manages themselves are not.

// Creating a Subset

WHOLE ORGANISATION VS SUBSET SCOPE

A sub-set is a part of your network that has been segregated by a firewall or VLAN at Layer 2 or Layer 3. Only these two methods are accepted. What you can still call your scope depends on whether that excluded segment retains internet access.

Scenario 1

EXCLUDING A NETWORK THAT RETAINS INTERNET ACCESS

The excluded segment still connects to the internet. This applies when you need to remove a network from scope - for example a development environment with unsupported tools, or a segment of a global company - but that network still needs internet access.

  • ✓Firewall or VLAN between in-scope and excluded segments
  • ✓Excluded segment can still access the internet
  • →Scope description: "Whole Organisation Excluding Dev Network"
Scenario 2

EXCLUDING A NETWORK WITH INTERNET ACCESS FULLY BLOCKED

The excluded segment has all inbound and outbound internet connections blocked at the boundary. A common example: an unsupported legacy server that you need out of scope but still communicates with other internal systems. Because it cannot reach the internet, it does not create a risk to the in-scope network.

  • ✓Firewall or VLAN between segments
  • ✓All internet access blocked on the excluded segment
  • →Scope description: "Whole Organisation"

Segregation must be at Layer 2 or Layer 3 of the OSI model

Only a firewall or VLAN at Layer 2 or Layer 3 creates a valid sub-set. Micro-segmentation (Layer 4+), user group policies, proxy servers, and individual device firewall rules are not accepted segregation methods and do not create a valid sub-set boundary.

// What Doesn't Work

WHAT CANNOT EXCLUDE ITEMS FROM SCOPE

Common misconceptions about what creates a scope boundary. None of the following are accepted as a way to exclude devices or networks from a Cyber Essentials assessment.

✗ PROXY SERVERS

A proxy server routes traffic but does not segregate the network. Devices behind a proxy are still in scope and must meet Cyber Essentials controls.

✗ DMZ

A DMZ cannot be assessed in isolation when it protects and routes traffic to an internal network. The DMZ, its boundary firewall, the internal firewall connecting the DMZ to the internal network, and all end-user devices on that internal network are in scope. A DMZ does not create a separate scope boundary.

✗ DEVICE FIREWALL RULES

Individual firewall rules applied to specific devices do not exclude those devices from scope. The rule applies at the device level, not the network boundary.

✗ MICRO-SEGMENTATION

Micro-segmentation operates at Layer 4 or above in the OSI model. Only Layer 2 (VLAN) or Layer 3 (firewall) segregation creates a valid sub-set boundary for Cyber Essentials.

✗ USER GROUPS

Restricting access via user group policies or permissions does not segregate the network. Users still access the same infrastructure and those devices remain in scope.

✗ KALI LINUX / PARROT OS

Operating systems designed for penetration testing - such as Kali Linux or Parrot OS - cannot be part of a Cyber Essentials certification, including virtual installations. If these are in your environment, they must be excluded via a valid sub-set.

// Special Cases

EDGE CASES AND SPECIFIC SCENARIOS

// Education

SCHOOLS, UNIVERSITIES AND STUDENT BYOD

Student-owned devices are the one recognised exception to the BYOD rule. Student BYOD can be excluded if placed on a designated student network that is segregated from the school or university's main network, with no access to organisational data. The scope can still be described as "whole organisation".

  • School-owned devices used by students are in scope
  • Loaned devices are out of scope while on the student network; back in scope when returned
  • Student accounts owned by the institution are in scope
  • Student BYOD accessing cloud services does not bring those devices in scope - but the cloud services must have controls applied
  • Staff BYOD cannot be moved out of scope
  • If students access your main network (not the segregated student network), their devices are in scope
// OT

OPERATIONAL TECHNOLOGY (OT)

Cyber Essentials focuses on internet-connected IT systems and does not explicitly address OT. OT should be appropriately isolated through network segmentation, monitoring and access controls. Where OT interfaces with IT - for example via shared networks or remote access - those interfaces must meet Cyber Essentials requirements. For further guidance, the NCSC Supply Chain Playbook covers OT considerations.

// Global Orgs

INTERNATIONAL AND MULTI-SITE ORGANISATIONS

There are no location restrictions on Cyber Essentials. Organisations based outside the UK can certify. For global companies, it is acceptable to certify a sub-set - for example the UK operation - provided the excluded networks are properly segregated. The scope description must clearly state what is included and excluded.

// CE Plus

CYBER ESSENTIALS PLUS SCOPE RULE

The scope of a Cyber Essentials Plus assessment must be identical to the scope of the Cyber Essentials certificate it is based on. You cannot narrow or expand the scope for Plus. If you want a different scope for CE Plus, you need a new Cyber Essentials certificate with that scope first. For CE Plus, assessors also distinguish between OS editions (Home, Professional) and versions (25H2, 26H1) for the purposes of device sampling - each combination is treated separately.

Not in scope: switches and printers

Network switches are not in scope for Cyber Essentials. Printers are also not in scope. Air-gapped equipment that never connects to the internet or an internet-connected network does not need to be declared. The focus is on devices that access or interact with the internet.

// What To Provide

SCOPING INFORMATION REQUIRED IN YOUR APPLICATION

The Cyber Essentials application asks you to describe your scope and list your devices. Here is what the assessor expects to see.

SCOPE DESCRIPTION

A clear written description of what is in and out of scope - for example "Whole organisation" or "Whole organisation excluding the development network". If creating a sub-set, explain the rationale and confirm that the excluded segment is properly segregated by firewall or VLAN.

DEVICE INVENTORY

The required information is make and operating system. This applies to laptops, desktops, mobile devices and servers. You do not need to list every device individually - counts by type, make and OS version are acceptable. For CE Plus, OS edition (Home, Professional) and version (e.g. 25H2, 26H1) must be distinguished separately for sampling purposes.

CLOUD SERVICES LIST

All cloud services your organisation uses must be listed. For each service, the application will ask which Cyber Essentials controls apply and how they are implemented. Whether your organisation or the provider is responsible for each control depends on the service type.

NETWORK BOUNDARY DESCRIPTION

The boundary of scope is the firewalls and routers forming the first line of defence between your networks and the internet. Control 1 (Firewalls) requirements apply to these devices. If you have created a sub-set, you must be able to explain and evidence the segregation method used.

// FAQ

SCOPING QUESTIONS ANSWERED

Whole organisation means no networks are excluded from the scope. All devices, cloud services, home workers and networks are included. It is the preferred approach and qualifies you for the included cyber liability insurance (UK-domiciled organisations with annual turnover below £20 million). Note: a segregated guest or student network with no access to organisational data can be excluded and the scope can still be described as "whole organisation" - this is a recognised exception, not a rule.
Yes - if they access organisational data or services. This includes personal phones used for work emails. Staff BYOD cannot be moved out of scope. Student BYOD is the one recognised exception: student-owned devices can be excluded if placed on a properly segregated student network with no access to organisational data, and the scope can still be described as "whole organisation".
Organisational data is any electronic data belonging to your organisation - emails, documents, database data, financial records. Organisational services are any software applications, cloud applications, cloud services, virtual desktops, and mobile device management (MDM) solutions owned or subscribed to by your organisation - for example Microsoft 365, Google Workspace, MDM containers, Citrix Desktop, VDI solutions, or RDP desktops. Any device that accesses either of these is in scope.
Yes. Every cloud service your organisation uses is in scope. You are responsible for ensuring Cyber Essentials controls are applied even where the cloud provider manages the infrastructure. Whether the provider or your organisation implements a specific control depends on the type of service (IaaS, PaaS, SaaS), but the responsibility sits with you as the applicant.
No. A proxy server routes traffic but does not create a segregated scope boundary. Devices behind a proxy are still in scope. Only a firewall or VLAN at Layer 2 or Layer 3 of the OSI model creates a valid sub-set.
No. A DMZ cannot be assessed in isolation when it protects and routes traffic to an internal network containing end-user devices. Everything is in scope: the DMZ itself, its boundary firewall, the internal firewall connecting the DMZ to the internal network, and all end-user devices on that internal network. A DMZ provides a security layer but does not create a separate Cyber Essentials scope boundary.
Segregation must be done using a firewall or VLAN at Layer 2 or Layer 3 of the OSI model. Micro-segmentation (Layer 4+), user group policies, proxy servers, and individual device firewall rules are not accepted. If the excluded segment retains internet access, the scope description must state the exclusion. If all internet access is blocked on the excluded segment, the scope can still be described as "whole organisation".
No. The scope of Cyber Essentials Plus must be identical to the scope of the Cyber Essentials certificate it is based on. You cannot narrow or expand it. If you need a different scope for Plus, you need a new Cyber Essentials certificate with that scope before proceeding to Plus.
No. Network switches are not in scope for Cyber Essentials. Printers are not in scope either. The focus is on end-user devices (laptops, desktops, phones, tablets, servers) and cloud services that access or handle organisational data. Air-gapped equipment that never connects to the internet or an internet-connected network does not need to be declared.
No. Operating systems designed for penetration testing - Kali Linux, Parrot OS and similar - cannot be part of a Cyber Essentials certification, including virtual installations. If these exist in your environment, they must be excluded using a valid sub-set (firewall or VLAN segregation). They cannot simply be declared as compliant.
Yes. Virtual machines and containers are in scope and the Cyber Essentials controls must be applied to them in the same way as to physical devices. Where using VDI, the endpoint devices that connect to the virtual desktop are also in scope - not just the virtual desktop server.
If a third party manages IT systems within your scope, those systems are still subject to Cyber Essentials controls and you as the applicant are responsible for ensuring controls are met. All third-party employees with access to your systems must have unique login credentials - shared accounts are not compliant. If your MSP, cloud provider or parent company delivers a control on your behalf, the evidence must come from them and you are responsible for obtaining it before the assessment.

UNSURE ABOUT YOUR SCOPE? WE CAN HELP.

Scoping is the first conversation we have with every new client. Talk through your setup before you commit - there is no obligation and no guesswork required. Vincent Cyber Defence is an IASME Approved Certification Body.