The five Cyber Essentials controls are: (1) Firewalls, (2) Secure Configuration, (3) User Access Control, (4) Malware Protection, and (5) Patch Management. All five must pass for a certificate to be issued. Under Danzell v3.3 (April 2026), user access control and patch management both carry auto-fail triggers that cause immediate failure regardless of performance on other controls.
WHY THE CONTROLS MATTER IN DETAIL
The question most organisations ask before certification is "do we have the basics covered?" The question they should ask is "do we meet each control precisely as the assessor will evaluate it?" There is a material difference. MFA enabled on admin accounts only is not the same as MFA enabled on all cloud services for all users - and since April 2026, the latter is an automatic failure if not in place.
Each control maps to a section of the IASME questionnaire. What follows is what the assessor is actually checking for each one, and where organisations most commonly fall short.
CONTROL 1: FIREWALLS
Every device in scope must be protected by a firewall configured to a default-deny policy - only traffic that is explicitly permitted should be allowed. At the network boundary this means a properly configured internet gateway or edge firewall. For devices that connect to the internet directly - laptops on public Wi-Fi, for example - a personal firewall on the device itself is also required.
The assessor is checking that inbound connections are restricted to what is necessary, that management interfaces (admin consoles, RDP, SSH) are not exposed to the internet, and that there is a documented rationale for open ports. Overly permissive rules, forgotten open ports, and devices operating outside the network perimeter without personal firewalls are the common failure points.
Common failures: RDP or SSH accessible from the internet; admin consoles with no IP restriction; devices used off-site without personal firewalls active.
CONTROL 2: SECURE CONFIGURATION
Devices and software must be configured securely before deployment and kept that way. Default passwords must be changed on all hardware and software - routers, switches, printers, cloud platforms, and applications. Unnecessary software must be removed. Unused accounts must be disabled. Auto-run and auto-play must be turned off on all in-scope devices.
The assessor is checking that devices are not left in factory configuration, that old accounts do not persist after staff leave, and that only software necessary for business purposes is installed.
Common failures: routers on default admin passwords; old accounts still active after staff leave; personal or unlicensed software on work devices; auto-run still enabled.
CONTROL 3: USER ACCESS CONTROL
Users should only have access to the data and systems they need for their role - the least privilege principle. Administrator accounts must be restricted to named individuals and used only for administrative tasks, not for general browsing or email. Under Danzell v3.3, MFA is mandatory for all users on every cloud service where the provider offers it. This is an automatic failure if not in place - not a finding you can fix after submission.
This control is currently the most commonly failed since the Danzell update. Many organisations had MFA enabled for admin accounts but not for all users. Under the new standard, every user on Microsoft 365, Google Workspace, and any cloud service with an MFA option must have it enabled.
Common failures: MFA not enforced for all users on Microsoft 365 or Google Workspace; shared or generic accounts in use; everyone in the business has admin rights; no process to remove access when staff leave.
CONTROL 4: MALWARE PROTECTION
All in-scope devices must be protected against malware. Anti-malware software with real-time scanning and automatic updates is the standard approach. The assessor checks that it is active, up to date, and configured to scan on access and on download. Email filtering and web proxy filtering that block malicious content before it reaches devices both satisfy elements of this control.
Application whitelisting - permitting only approved software to run - is an alternative to anti-malware and is accepted under the standard for organisations that have it in place.
Common failures: AV disabled or not updated on specific devices; excluded folders creating blind spots; no email filtering; AV installed but alerts not monitored or acted on.
CONTROL 5: PATCH MANAGEMENT
All software on in-scope devices must be licensed, supported, and patched. The Danzell update made this two separate auto-fail questions: A6.4 covers operating systems and firmware, A6.5 covers applications. Both require patching within 14 days where a vulnerability rated CVSS 7.0 or above has been publicly disclosed. End-of-life software is not permitted on any device with internet access.
The 14-day clock starts from when the patch is made available, not when you become aware of it. This means patch management needs to be a process, not a one-off activity. Third-party applications - browsers, PDF readers, Office, Adobe products - are covered by A6.5 and must be on the same cycle as the operating system.
Common failures: third-party applications running behind the OS patch cycle; EOL operating systems still in use; no process for tracking vulnerability disclosures; software installed and forgotten with no update mechanism.
Preparing for certification? Vincent Cyber Defence reviews your controls against all five requirements before formal submission - so gaps are fixed before the assessor sees them. Fixed price from £320 + VAT.