WHAT IS CYBER ESSENTIALS PLUS?
Cyber Essentials Plus is the higher level of the UK government-backed Cyber Essentials scheme. It adds an independent technical audit to the standard CE self-assessment. An IASME-approved assessor remotely tests your systems via screen share to verify that the five security controls are correctly implemented in practice - not just documented on a form.
CE Plus is assessed under the Danzell v3.3 standard (current as of 2026). It covers the same five controls as standard CE - firewalls, secure configuration, user access control, malware protection, and patch management - but verifies them through live technical testing. For organisations that need to demonstrate a higher level of independent assurance, CE Plus is the recognised route.
Both standard CE and CE Plus are issued by IASME Approved Certification Bodies - organisations that have been licensed by IASME to deliver the scheme and issue certificates directly.
Looking for CE Plus certification? Vincent Cyber Defence is an IASME Approved Body. pre-assessment review included as standard - we review your controls before the audit begins. Fixed pricing from £1,195 + VAT.
HOW CE PLUS DIFFERS FROM STANDARD CYBER ESSENTIALS
Standard Cyber Essentials is a verified self-assessment. You answer a questionnaire about how your security controls are configured; a certification body reviews your answers and issues a certificate if they are met. The assessor does not view your systems.
CE Plus adds a hands-on technical audit on top of that. The same five controls apply - but instead of reviewing written answers, an assessor remotely connects to a sample of your devices and actively tests that each control is working correctly. If your answers say you apply patches within 14 days but your devices reveal outstanding critical patches, that is a failure. The gap between documented intent and actual implementation is exactly what CE Plus is designed to find.
That distinction matters for buyers and prime contractors. A CE Plus certificate means an independent assessor verified the controls in your live environment - not that an organisation described its controls and those descriptions were checked for internal consistency. That is why CE Plus is specified rather than CE basic when a higher standard of assurance is required.
WHO NEEDS CYBER ESSENTIALS PLUS?
Whether you need CE Plus - rather than standard CE - depends on what your contract, tender, or procurement requires. The common contexts where CE Plus is specified:
- MOD contracts at higher risk levels. Defence Cyber Certification Levels 2 and 3 (High and Substantial risk profiles under CSM v4) require CE Plus. DCC Level 0 and Level 1 require standard CE only. DCC Level 0 explained →
- Central government and NHS procurement under PPN 014. PPN 014 requires CE or CE Plus for in-scope contracts - buyers set the level. NHS buyers frequently specify CE Plus for contracts involving patient data or clinical systems. The procurement documentation will state which level applies.
- NHS DTAC. DTAC's C3.1 requires a CE certificate as the baseline technical security evidence. CE Plus satisfies this and also addresses higher-tier buyer requirements. DTAC is applied by the procuring NHS body - check whether your buyer requires CE Plus specifically.
- Enterprise and prime contractor supply chains. A growing number of FTSE 250 companies and prime contractors specify CE Plus for critical or higher-risk suppliers. Supply chain questionnaires increasingly ask for CE Plus rather than CE basic for organisations handling sensitive data or providing critical services.
- Cyber liability insurance. Some insurers require CE Plus rather than CE basic for coverage at higher risk levels or above certain revenue thresholds. Check your policy or renewal requirements.
If you are unsure which level your contract requires, the right question is not "is CE Plus worth it?" but "what does my contract, tender, or insurer specify?" Standard CE will not substitute for CE Plus where CE Plus is the stated requirement.
CE Plus is also the right choice for organisations that want to demonstrate a higher level of assurance to their customers. A CE Plus certificate signals that your controls have been independently verified in your live environment - not just self-reported. For organisations that handle sensitive client data or operate in regulated sectors, CE Plus is increasingly the expected standard rather than the exception.
THE PREREQUISITE: STANDARD CYBER ESSENTIALS FIRST
CE Plus cannot begin until you hold a valid Cyber Essentials certificate. You complete the CE self-assessment questionnaire first, receive your CE basic certificate, and the technical audit follows. Once CE basic is certified, you have 90 days (3 months) to complete and pass CE Plus.
If the 90-day window expires without a pass, your Plus application closes and you need to re-certify at CE basic level before restarting - which incurs an additional cost. In practice, most organisations complete CE and CE Plus as part of the same engagement and move straight into CE Plus preparation after CE basic is confirmed.
Important: the 30-day remediation window (if issues are found during the audit) runs inside the 90-day clock, not separately. Plan for the whole engagement to complete comfortably within 90 days from CE basic.
THE FIVE CONTROLS AND HOW EACH IS AUDITED
CE Plus tests the same five controls as standard Cyber Essentials. The difference is how each is verified.
1. Firewalls and Internet Gateways
Your boundary devices must restrict inbound and outbound traffic to only what is necessary. The assessor conducts an external vulnerability scan of your internet-facing systems, checking for open ports that should be closed, unnecessary services exposed to the internet, and misconfigured boundary devices.
Software firewalls on individual devices are also checked - particularly important for laptops used outside the corporate network. A remote worker's device connects directly to the internet with no corporate boundary firewall between it and the web. The software firewall on that device is the boundary protection, and it must be enabled and configured.
2. Secure Configuration
Devices must be configured securely: unnecessary accounts, software, and services removed or disabled; default credentials changed; auto-run features disabled. The assessor checks sampled devices for:
- Default accounts removed or disabled
- Default passwords changed on network equipment and cloud services
- Auto-run and auto-play disabled
- Unused software removed (reducing the attack surface)
- Standard users cannot install software or change security settings
3. User Access Control
Accounts must be managed with least privilege. Standard users should not have administrator rights for day-to-day work. The assessor confirms that users on sampled devices are logged in with standard (non-admin) accounts. Privileged accounts must only be used when administrative tasks require them, not as the default working account.
Under Danzell v3.3, MFA is required for all cloud service accounts where MFA is available. This sits within the user access control framework - an account without MFA where the service offers it is an auto-fail condition. More on MFA below.
4. Malware Protection
Endpoint protection must be installed, actively running, and up to date with current definitions on all in-scope devices. The assessor checks:
- Anti-malware or endpoint protection is installed and active
- Signatures are up to date (automatic updates must be enabled)
- Real-time scanning is enabled
- Standard users cannot disable endpoint protection
In addition, the assessor runs two malicious content delivery tests - sub-tests 3.1.1 and 3.1.2 - which test whether your email security and browser/endpoint protection can block malicious executables before they reach users.
5. Patch Management
All software must be patched within 14 days of a critical or high-severity update being released (CVSS v3 score 7.0 or above). This is assessed under two separate questions: A6.4 covers OS and firmware, and A6.5 covers applications. Both are auto-fail conditions if any in-scope device has critical or high-severity patches outstanding beyond the 14-day window.
Unsupported software - products that no longer receive security updates - is also a failure point. If an in-scope device runs an end-of-life operating system or an unsupported application, it cannot be patched and therefore cannot meet this control.
DEVICE SAMPLING: HOW THE ASSESSOR PICKS WHAT TO TEST
The assessor does not test every device in your organisation. Instead, they select a representative sample based on each specific OS type and build - for example, Windows 11 24H2 Pro, macOS Sequoia 15.4, iOS 18.3. Devices that share the same OS version and edition are treated as one population for sampling purposes.
| Devices per OS Version & Edition | Minimum Sample |
|---|---|
| 1 | 1 |
| 2 - 5 | 2 |
| 6 - 19 | 3 |
| 20 - 60 | 4 |
| 61+ | 5 |
The assessor selects the sample independently - you cannot choose which devices are tested. That independence is deliberate: it means the audit reflects the real state of your estate, not a curated subset. All in-scope devices should be in the same state - patched, protected, and configured correctly - not just the ones you expect to be tested.
If a failure is found in the first sample and the issue is remediated within the 30-day window, the assessor retests the original devices and selects a second independent sample from the remaining estate to verify that the fix was applied consistently - not just to the devices that failed the first round.
SCOPING: WHAT MUST BE IN AND WHAT CAN BE OUT
Scope determines what the CE Plus audit covers. Getting scope right is one of the most important preparation steps.
What must be in scope
End-user devices cannot be excluded. Any device used by a person as part of your organisation that connects to the internet is in scope: laptops, desktops, smartphones, tablets. You cannot exclude a category of end-user devices on the grounds that they are personal devices (BYOD), that they are rarely used, or that they are not managed by IT.
Anything on a network segment that reaches the internet is in scope. If a device has a network path to the internet - directly or via your corporate network - it must be included unless it falls into a permissible exclusion category.
What can legitimately be excluded
- Hyperscaler physical infrastructure. AWS, Azure, and GCP physical servers and network fabric are excluded - these providers hold their own CE Plus. What your organisation builds on top of that infrastructure (your VMs, containers, and configurations) is not excluded.
- PaaS (Azure App Service, AWS RDS, Google Cloud Run). Your organisation's configuration, access controls, and admin accounts are in scope; the platform layer managed by the hyperscaler is excluded.
- Properly segregated operational technology (OT) and clinical devices. Industrial control systems, SCADA, and clinical or medical devices on a properly segregated network that has no internet path can be excluded. If the OT network is flat - sharing a network with office IT that connects to the internet - those devices are in scope. Air-gapped or genuinely isolated segments can be scoped out.
The scope boundary must be clearly documented and defensible. An underdefined scope is one of the most common reasons an assessment stalls. Define your scope clearly before engaging a certification body, and document any exclusions with a clear rationale.
CLOUD SERVICES AND MICROSOFT 365
Cloud services used by your organisation - Microsoft 365, Google Workspace, and any SaaS platforms - are assessed for access control and MFA configuration. The assessor typically checks:
- MFA enforcement. All user accounts on cloud services must have MFA enabled where the service offers it - not just admins. The assessor usually checks this via the admin console (for example, Microsoft Entra ID conditional access policies or Google Admin security settings) and may ask a user to demonstrate a login to confirm the prompt is enforced.
- Admin account separation. Admin accounts in Microsoft 365 and Google Workspace should be separate from standard user accounts - a named individual should not use the same account for day-to-day email and global administration.
- Conditional access and security baselines. Microsoft 365 tenants are assessed for the security baseline configuration. Organisations running Microsoft 365 without Conditional Access or equivalent policy enforcement are likely to have MFA gaps.
REMOTE AND HYBRID WORKERS
Devices used by remote or hybrid workers are in scope if they connect to the internet for organisational work. This includes personal devices used for work email or organisational data (BYOD), which must meet the same security controls as corporate devices.
For remote workers, two controls require particular attention:
- Software firewall. A device that connects directly to the internet without a corporate boundary firewall relies entirely on its own software firewall for boundary protection. This must be enabled and configured on every remote worker's device.
- Endpoint protection. Anti-malware must be active and cannot be disabled by the standard user. For BYOD devices, this sometimes requires MDM enrolment or an agreed acceptable use policy that mandates endpoint protection - check that your BYOD policy translates into actual control enforcement, not just a document the user signed.
MFA must be enforced for remote workers accessing cloud services and remote access mechanisms (VPN, RDP). There are no exceptions for remote workers that would not apply to office-based users.
THE MALICIOUS CONTENT TESTS: SUB-TESTS 3.1.1 AND 3.1.2
Two specific sub-tests often catch organisations out because they are misunderstood. Sub-tests 3.1.1 and 3.1.2 are email and browser malware delivery tests. They are not phishing simulation tests.
Sub-test 3.1.1 - Email malware delivery
The assessor attempts to deliver a simulated malicious executable via email to verify that your email security blocks or quarantines it before it reaches the inbox. This tests whether your email filtering - Microsoft Defender for Office 365, Google Workspace security, or equivalent - can intercept a malicious attachment or executable before it reaches the recipient.
If the test file arrives in the inbox and can be opened, that is a failure. The assessor is not testing whether users click on suspicious links - they are testing whether the technical controls stop the malicious content at the email layer before the user even sees it.
Sub-test 3.1.2 - Browser malware delivery
The assessor attempts to download a simulated malicious executable via a browser to verify that your endpoint protection or web filtering prevents the download from completing. This tests whether the endpoint or network layer blocks the file before it lands on the device.
If the test file downloads successfully to the device, that is a failure. This test is distinct from 3.1.1 - an organisation can pass one and fail the other, depending on how their email and endpoint controls are configured.
What "malicious content" means here. The test files are standardised EICAR-format or equivalent simulated executables - not actual malware. What matters is that your controls treat them as malicious and block them. If your security software does not detect the test file, it would not detect real malware with the same characteristics.
MFA REQUIREMENTS UNDER DANZELL V3.3
Multi-factor authentication requirements under Danzell v3.3 are specific: where a cloud service or remote access mechanism offers MFA, it must be enabled. Failure to do so is an auto-fail condition.
MFA must be enforced for:
- All cloud service accounts where MFA is available. Microsoft 365, Google Workspace, AWS, Azure, any SaaS platform - every user account, not just admins.
- All remote access mechanisms. VPN, RDP gateways, remote desktop services, SSH access to servers - any mechanism that provides remote access to organisational resources must require MFA.
- All administrator accounts. Whether cloud or on-premises, all admin accounts must have MFA.
The second factor must be independent of the device being authenticated. SMS, authenticator apps (Microsoft Authenticator, Google Authenticator, Authy), hardware tokens (YubiKey), and passkeys all qualify. A second factor that is delivered to the same device being used to log in does not fully meet the independence requirement in some configurations - discuss your specific setup with your assessor before the audit if you are unsure.
Important: MFA enforcement means it is applied as a mandatory policy, not simply offered to users as an option they can choose to enable. If users can bypass MFA by clicking "skip" or by using a legacy authentication protocol, the control is not met.
AUTO-FAIL CONDITIONS
Auto-fail conditions immediately fail the CE Plus assessment regardless of how well other controls perform. The main auto-fail conditions under Danzell v3.3 are:
- Critical or high-severity vulnerability on an external-facing system. Found during the external scan. Any CVSS v3 score of 7.0 or above on an internet-facing system is an automatic failure.
- OS or firmware patching - A6.4. Any in-scope device with a critical or high-severity OS or firmware patch outstanding beyond 14 days of release.
- Application patching - A6.5. Any in-scope device with a critical or high-severity application patch outstanding beyond 14 days of release. A6.4 and A6.5 are two separate questions - passing one does not compensate for failing the other.
- MFA not enabled on a service that offers it. Any cloud service or remote access mechanism in scope where MFA is available but not enforced.
- Malicious content test file delivered or downloaded. If sub-test 3.1.1 (email) or 3.1.2 (browser) fails - the test file reaches the inbox or downloads to a device.
An auto-fail on any of these conditions starts the 30-day remediation clock. You have 30 days from the assessment start date - not from the date the failure was identified - to remediate and present the remediated state for retesting.
HOW THE CE PLUS AUDIT IS SCORED
CE Plus is a pass or fail - there is no partial pass or percentage score. All five controls must be met. If any control fails, the assessment fails. If a failure occurs due to an auto-fail condition, the assessment fails at that point regardless of how other controls performed.
The audit proceeds as follows:
- External vulnerability scan of internet-facing systems. Any critical or high-severity finding is an immediate auto-fail.
- Device sample selected by the assessor per OS type and build.
- Screen share session: assessor works through each sampled device checking patch levels, endpoint protection, user account type, software firewall, and secure configuration.
- Cloud services and MFA checked via admin console review and live login verification.
- Malicious content delivery tests (3.1.1 email, 3.1.2 browser).
- Results confirmed: pass, or failure with specific findings and the 30-day remediation window open.
On a pass, your CE Plus certificate is issued through IASME's BlockMark system as a verifiable digital certificate. Your BlockMark badge links to a publicly verifiable record on the IASME register, so buyers and prime contractors can confirm your certification is current without contacting you.
WHAT HAPPENS IF YOU FAIL
If the audit identifies failures, you have 30 days from the assessment start date to remediate them. Your assessor will tell you exactly what needs fixing. After remediation:
- The assessor retests the original sample devices to confirm the specific issues are resolved.
- The assessor selects a second independent sample from the remaining devices in that OS population to verify the fix was applied consistently across the estate - not just to the devices that failed the first round.
If unresolved vulnerabilities appear in the second sample, the CE Plus assessment fails automatically. At that point, your underlying CE basic certificate is revoked. You would then need to re-certify at CE basic level before restarting CE Plus - incurring the cost of an additional CE basic certification and a new CE Plus engagement.
The 30-day remediation window runs inside the 90-day window from your CE basic certification date, not separately. If remediation takes the full 30 days, you have 60 days from the original CE basic to complete the retest and confirm a pass.
The most common reason remediation fails the second round: the fix was applied to the specific devices that failed but not rolled out consistently to the rest of the estate. Treat the first sample failure as a signal to check the whole estate, not just the affected devices.
HOW LONG IS A CE PLUS CERTIFICATE VALID?
A CE Plus certificate is valid for 12 months from the date of certification - the same as standard Cyber Essentials. You receive two certificates from a successful CE Plus engagement: a CE basic certificate and a CE Plus certificate. Both carry 12-month validity and both must be renewed annually.
If your CE basic certificate lapses, you cannot renew CE Plus without first re-certifying at CE basic level. The practical implication is that CE basic and CE Plus are renewed together annually - most organisations treat them as a single annual engagement.
IASME issues certificates and verifiable badges through BlockMark. Your CE Plus badge links to a publicly verifiable record on the IASME register. Buyers and primes can verify your status directly without calling you - the badge is designed for this purpose and is worth displaying prominently on your website and in tender responses.
HOW MUCH DOES CYBER ESSENTIALS PLUS COST?
CE Plus pricing scales by organisation size. At Vincent Cyber Defence, prices are fixed with the IASME certification fee included:
- Micro (0-9 employees): £1,195 + VAT
- Small (10-49 employees): £1,495 + VAT
- Medium (50-249 employees): £2,195 + VAT
- Large (250+ employees): £3,495 + VAT
A CE and CE Plus bundle is available at a saving over separate purchases: Micro £1,395 + VAT, Small £1,795 + VAT, Medium £2,495 + VAT, Large £3,795 + VAT. All prices include both the CE and CE Plus IASME certification fees. View full CE Plus pricing →
CE PLUS PREPARATION CHECKLIST
Use this checklist before the audit begins. All items should be in place before the formal assessment starts.
- Hold a valid Cyber Essentials certificate issued within the last 90 days (or complete CE basic as the first step of the same engagement).
- Apply all outstanding critical and high-severity patches to operating systems, firmware, browsers, and applications across all in-scope devices. Check CVSS scores - anything 7.0 or above within the past 14 days must be applied before the audit.
- Remove or update all end-of-life software. Unsupported OS versions and applications that no longer receive security updates cannot be patched and will fail the patching controls.
- Enforce MFA on all cloud services. Microsoft 365, Google Workspace, and any SaaS platforms - all user accounts, not just admins. Block legacy authentication protocols.
- Enforce MFA on all remote access mechanisms. VPN, RDP gateways, remote desktop services. No exceptions for specific users or account types.
- Confirm endpoint protection is installed, active, and up to date on every in-scope device including mobile and remote worker devices. Verify that standard users cannot disable it.
- Enable software firewalls on all devices, particularly remote worker laptops that connect directly to the internet.
- Check email security blocking. Run an internal test to verify that executable attachments are blocked or quarantined before reaching inboxes. If you are using Microsoft 365, review your Defender for Office 365 policy - ensure Safe Attachments and anti-malware policies are active.
- Check browser and endpoint download blocking. Verify that attempts to download executables from the web are blocked by endpoint protection or web filtering. This is what sub-test 3.1.2 tests.
- Confirm scope is defined and documented. List all in-scope devices by OS type and build. Document any exclusions with a clear rationale. Brief your assessor on scope before the audit day.
- Have someone available on audit day to share their screen and navigate each sampled device as the assessor directs. This is typically an IT administrator or the person responsible for each device type. Confirm availability in advance.
- Confirm internet-facing IPs and domains so the assessor can run the external vulnerability scan. Include all public IPs, web servers, email servers, and any other externally accessible systems.
For a detailed per-control preparation guide, see our CE Plus readiness checklist →
HOW TO GET CE PLUS CERTIFIED
pre-assessment review included as standard. At Vincent Cyber Defence, we review your controls before the formal audit begins - identifying gaps and telling you what needs fixing before the 90-day clock starts. We do not start the audit until you are ready. That is the difference between a first-time pass focus and a process that starts the clock and hopes for the best.
CE Plus assessments can only be delivered by IASME Approved Certification Bodies. Vincent Cyber Defence is approved to deliver CE Plus and issue certificates directly. Our process:
- Initial conversation. We confirm your scope, timeline, and any constraints - cloud-only, remote workers, BYOD, managed services. This is the point to discuss anything non-standard before the engagement formally starts.
- CE basic self-assessment. You complete the CE questionnaire with our guidance. We review your answers before final submission to identify gaps and fix them before the formal assessment starts. Certificate issued on confirmation.
- pre-assessment review. We review your controls against the CE Plus audit requirements - patching, MFA, endpoint protection, email security. Any gaps identified here are fixed before the audit day. The formal audit clock does not start until you are ready.
- CE Plus technical audit. Remote screen share session. Assessor selects device sample, checks each control, runs external scan and malicious content tests. Usually completed in one session.
- Certificate issued. On a pass, CE Plus certificate and BlockMark badge issued directly by Vincent Cyber Defence as an IASME Approved Body. Usually within 3-5 business days of audit completion.
Your named lead assessor works with you throughout - the same person from initial scoping through to your certificate. No handoffs to a support team or account manager.
CE Plus is fixed-priced from £1,195 + VAT including the IASME certification fee - view CE Plus pricing →
✓ Confirm your environment is ready. Use our free CE Plus readiness checklist to work through all five controls before your audit day.
Need CE Plus certification? Fixed-priced from £1,195 + VAT - IASME certification fee included, pre-assessment review as standard, 12-month certificate. We guide UK organisations through CE Plus with a first-time pass focus.